Home chevron_right Products chevron_right Specialty Solutions chevron_right LineaSens® Proprietary, Hydrogen Insensitive Core Graded-Index Multimode 50 µm Optical Fiber
Descontinuado
Code - 06735-01

LineaSens® Proprietary, Hydrogen Insensitive Core Graded-Index Multimode 50 µm Optical Fiber

This optical fiber is designed for distributed temperature sensing and communications in applications where hydrogen diffusion is a concern, and in temperatures up to 293 ºC for long durations (~ up to 20 years, performance and reliability will vary depending on installation environment. Consult Lightera for guidance). The waveguide features a proprietary, hydrogen insensitive core structure to minimize the effects of hydrogen darkening and also features a thin, hard, polyimide coating for excellent chemical resistance and thermal stability at elevated temperatures.

This optical fiber is designed for distributed temperature sensing and communications in applications where hydrogen diffusion is a concern, and in temperatures up to 293 ºC for long durations (~ up to 20 years, performance and reliability will vary depending on installation environment. Consult Lightera for guidance). The waveguide features a proprietary, hydrogen insensitive core structure to minimize the effects of hydrogen darkening and also features a thin, hard, polyimide coating for excellent chemical resistance and thermal stability at elevated temperatures.

Features

  • Improved Waveguide Resists Hydrogen Darkening
  • Graded-Index 50/125 Fiber Structure
  • PYROCOAT® K Coating Industry-Leading Thermal Stability

Benefits

  • Minimizes permanent losses due to hydrogen ingression in harsh conditions
  • Compatible with most commercially available Distributed Temperature Sensing (DTS) interrogators; can also be fusion spliced to similar hydrogen insensitive core optical fiber, and traditional lead-in optical fibers
  • Thin, hard coating provides excellent thermal stability, plus chemical and abrasion resistance in a small cross-section of 155 µm

Product Description

This optical fiber is designed for distributed temperature sensing and communications in applications where hydrogen diffusion is a concern, and in temperatures up to 293 ºC for long durations (~ up to 20 years, performance and reliability will vary depending on installation environment. Consult Lightera for guidance). The waveguide features a proprietary, hydrogen insensitive core structure to minimize the effects of hydrogen darkening and also features a thin, hard, polyimide coating for excellent chemical resistance and thermal stability at elevated temperatures.

Product Specifications

Product Specifications
Product Description LineaSens® Proprietary, Hydrogen Insensitive Core GI MM 50 Optical Fiber (PYROCOAT® K Coating)
Item Number F80403
Description GEO50-H Geophysical Graded-Index Optical Fiber – Hydrogen Resistant, PYROCOAT* K
Type Multimode Graded-Index
Numerical Aperture 0.20
Attenuation @ 850 nm ≤ 4.0 dB/km
Attenuation @ 1300 nm ≤ 2.0 dB/km
Bandwidth OFL @ 850 nm ≥ 400 Mhz-km
Bandwidth OFL @ 1300 nm ≥ 400 Mhz-km
Core Diameter 50 ± 3 µm
Clad Diameter 125 ± 2 µm
Coating Diameter 155 ± 5 µm
Cladding Non-Circularity ≤ 2.0%
Core Non-Circularity ≤ 5.0%
Hermetic Carbon Layer None
Operating Temperature -198 to +340 ºC
Short Term Excursions (24 hrs.) Up to 450 ºC
Coating Material PYROCOAT K
Short-Term Bend Radius (Mechanical) ≥ 8 mm
Long-Term Bend Radius (Mechanical) ≥ 10 mm
Proof Test Level 200 kpsi (1.38 Gpa)
Note * Hydrogen diffusion performance curve on right

Hydrogen Ingression Performance

Hydrogen Ingression Performance
Hydrogen Concentration Partial Pressure (PSI) Temperature (ºC) Duration (Days) H2 Induced Loss @ 1060 Nm
5% 1,500 250 23 < 1.0 dB/km
5% 1,500 350 10 < 1.0 dB/km

Image

LineaSens® Proprietary, Hydrogen Insensitive Core Graded-Index Multimode 50 µm Optical Fiber

Comparison

Comparison
Item Commercially Available Polyimide-Coated Fibers PYROCOAT® K
Lifetime at 275 ºC 4 years 80 years
Lifetime at 300 ºC 0.8 years 13 years
Lifetime at 325 ºC 70 days 2.2 years
Lifetime at 350 ºC 18 days 160 days
20-year Continuous Upper Use Temperature 250 ºC 293 ºC
Fiber/Metal Interaction at 300 ºC Fiber sticks to metal Fiber does not stick to metal
Aging in distilled water, 200ºC, 2000 psi, 7 days Coating material degrades No coating degradation
Aging in sea water, 100ºC, 2000 psi, 14 days No coating degradation No coating degradation
Aging in mineral oil, 250ºC, 2000 psi, 10 days No coating degradation No coating degradation
Aging in isopropanol, 250ºC, 1500 psi, 7 days No coating degradation No coating degradation
The lifetimes are based on 25% loss of the initial coating mass criterion. For details, see A. A. Stolov, D. A Simoff, J. Li, Thermal Stability of Specialty Optical Fibers. J. Lightwave Technol., 2008, V 26, N 20, P. 3443-3451.

Contact Information

For additional information please contact your sales representative. You can also visit our website at www.lightera.com or call 1-888-FIBERHELP (1-888-342-3743) USA or 1-770-798-555 outside the USA. For a full list of our certifications, visit our website.

Trademark Notice and Disclaimer

Lightera reserves the right to make changes to the product(s) described in this document at any time without notice. This document is for informational purposes only and is not intended to modify or supplement any Lightera warranties or specifications relating to any of its products or services.

Compare products and choose the best one

Compare features, sizes, models to find the perfect option for you

Compare products

Not available in your language
Americas Asia & Oceania Africa Europe Middle East