- Optical Fibers 200 µm
- Gel-filled Buffer Tubes
- Non-metallic Central Member
- Water Blocking Material
- Double Layer of glass yarns
- Ripcord
- PE-Jacket
Loose Tube Fibre Optic Outdoor Cable 36 Element All Dielectric Dry Core Design MiDia®200 Dielectric Rodent Protected
Loose Tube Fibre Optic Outdoor Cable 36 Element All Dielectric Dry Core Design MiDia®200 Dielectric Rodent Protected
Version illustrated is the 864 Fiber Cable
Product Specification | |||||||
---|---|---|---|---|---|---|---|
Fiber Count | Tubes | Core Design | Outer Diameter [mm] | Cable Weight [kg/km] | Standard Length [m] | AT-Code** | |
24 Fibers Per Tube | |||||||
864 | 36 | 1 +36 | 17.8 | 265 | 2000/4000 | AT-[][][]5XCF-864 | |
This table shows nominal diameter and weight values which may differ in shipments. **Please refer to the LIGHTERA AT- Code. The blanks specify the fiber type. |
Identification Fiber Color Code | |
---|---|
1 | Blue |
2 | Orange |
3 | Green |
4 | Brown |
5 | Grey |
6 | White |
7 | Red |
8 | Black |
9 | Yellow |
10 | Violet |
11 | Rose |
12 | Aqua |
13 | Blue*** |
14 | Orange* |
15 | Green*** |
16 | Brown* |
17 | Grey*** |
18 | White*** |
19 | Red*** |
20 | Natural |
21 | Yellow** |
22 | Violet*** |
23 | Rose*** |
24 | Aqua*** |
Note | *** Black Ring |
Identification Tube Color Code Inner Layer | |
---|---|
1+13* | Blue |
2+14* | Orange |
3+15* | Green |
4 | Brown |
5 | Grey |
6 | White |
7 | Red |
8 | Black |
9 | Yellow |
10 | Violet |
11 | Rose |
12 | Aqua |
Identification Tube Color Code Outer Layer | ||
---|---|---|
1+13* | Blue | |
2+14* | Orange | |
3+15* | Green | |
4+16* | Brown | |
5+17* | Grey | |
6+18* | White | |
7+19* | Red | |
8 | Black | |
9+20* | Yellow | |
10+21* | Violet | |
11 | Rose | |
12 | Aqua | |
Note | * Tube marked with black marker Alternative tube color code available on request |
LIGHTERA OPTICAL CABLE MIDIA200 DIELECTRIC RODENT PROTECTED [ID] [MM/YYYY] [Handset Sign] xxxF [Meter Marking]
Alternative sheath printing available on request.
In case of order the exact sheath printing text will be clarified with the customer.
Mechanical Properties and Environmental Behavior | |||
---|---|---|---|
Tests according to IEC 60794 | |||
Parameter | Requirement | Value | |
Tensile Performance: IEC 60794-1-21-E1A and E1B |
Long term load | – No attenuation increase* – No fiber strain |
Load: 1000 N |
Short term load, during installation | – No changes in attenuation before versus after load – Max. fiber strain 0.33% |
Load: 2700 N | |
Crush Performance: IEC 60794-1-21-E3A |
Long term load | – No attenuation increase* | Load (Plate / Plate): 500 N |
Short term load | – No changes in attenuation before versus after load – No damage** |
Load (Plate / Plate): 2000 N | |
Bending Performance: IEC 60794-1-21-E11 |
Handling fixed installed | – No attenuation increase* | Bend radius: 180 mm |
During installation (under load) | – No changes in attenuation before versus after load | Bend radius: 360 mm | |
Temperatures: IEC 60794-1-22-F1 |
Operation Installation Storage/Shipping |
– No attenuation increase* | -30 to +60°C -15 to +40°C -40 to +60°C |
* No changes in attenuation means that any changes in measurement value, either positive or negative within the uncertainty of measurement shall be ignored. The total uncertainty of measurement shall be less than or equal to 0.05 dB. ** Mechanical damage – when examined visually without magnification, there shall be no evidence of damage to the sheath. The imprint of plates will not be considered as damage. |
Shipping Information | |||
---|---|---|---|
Cable Length | Drum Diameter | Drum Width | Shipping Weight (calc.) Cable + Drum |
2000 m | 1550 mm | 1060 mm | 660 Kg |
4000 m | 1700 mm | 1060 mm | 1230 Kg |
The shipping information are given for one-way reels. Reusable reels are available on request. |
The information is believed to be accurate at time of issue.