Home chevron_right Products chevron_right Equipment chevron_right PDU- LASERWAY-2.0 DC-DC MODULE
Descontinuado
Code - 37150004

PDU- LASERWAY-2.0 DC-DC MODULE

The PDU-Laserway unit has two versions: AC/DC, with an input of 90 VAC to 250 VAC;DC/DC, with an input of -38 VDC to -60 VDC. The internal power module converts the input voltage to -54 V and powers the PSE module. The PSE module distributes the -54 V voltage to eight of -54 VDC / 1.15 A outputs each.The outputs are independent of each other and are protected against overcurrent and short circuit. The module has protection against voltage surges, both at the input and at each of the outputs and the access to the outputs is made through 8 electrical terminals in pairs, with polarity identified on the front of the PSE module.The Optical module receives a fiber cable and distributes the signal to eight optical connectors. The PDU-Laserway 2.0 will allow the use of hybrid cable and field connectorization and can be mounted on a wall, electro-rail, DIN rail, 19” rack, or airtight box. The maximum electric power available per PDU port is 62 W.Please check availability in your region.

The PDU-Laserway unit has two versions: AC/DC, with an input of 90 VAC to 250 VAC;DC/DC, with an input of -38 VDC to -60 VDC. The internal power module converts the input voltage to -54 V and powers the PSE module. The PSE module distributes the -54 V voltage to eight of -54 VDC / 1.15 A outputs each.The outputs are independent of each other and are protected against overcurrent and short circuit. The module has protection against voltage surges, both at the input and at each of the outputs and the access to the outputs is made through 8 electrical terminals in pairs, with polarity identified on the front of the PSE module.The Optical module receives a fiber cable and distributes the signal to eight optical connectors. The PDU-Laserway 2.0 will allow the use of hybrid cable and field connectorization and can be mounted on a wall, electro-rail, DIN rail, 19” rack, or airtight box. The maximum electric power available per PDU port is 62 W.Please check availability in your region.

Description

The Laserway 2.0 Power Distribution Unit (PDU) was developed to operate in conjunction with an LGX cassette, as a consolidation point for structured cabling.

From this consolidation point, the installation will follow with a hybrid cable to the ONT, thus providing remote power to the system.

The PDU-Laserway unit was developed in two versions: one, AC / DC, with input from 90 VAC to 250 VAC and another, DC / DC, with input from 24 VDC to 48 VCC (20-60V). The internal power module converts the input voltage to -54 V and supplies the PSE module.

The PSE module distributes the -54 V voltage to eight -54 VDC / 1.15 A outputs each. The outputs are independent of each other and are protected against overcurrent and short circuit. The module has protection against voltage surges, both at the input and at each of the outputs.

The access to the outputs is made through 8 electrical terminals in pairs, with polarity identified on the front of the PSE module.

The Optical module receives a fiber cable and distributes the signal to eight optical connectors.

The PDU-Laserway 2.0 will allow the use of hybrid cable and connectorization in the field. The unit can be mounted on a wall, electro-rail, DIN rail, 19 ”rack or airtight box.

In case of failure, both the optical module and the PSE module can be replaced, avoiding the need to replace the entire Laserway PDU unit.

The PDU-Laserway 2.0 has forced ventilation to guarantee the functioning of the system within the specified temperature range.

Gross Unit Weight

1.9 kg (PDU unit equipped)

Dimension

121x132x173 mm

Material

Metal box

Power Connection

Primary Power Source Redundant DC inputs (A/B) from 24 VDC to 48 VDC (20-60V) or from 90 VAC to 250 VAC (AC version), full range.
Number of Independent Outputs 8 electric and 8 optical
Voltage at each Output -54 VDC ± 1V
Maximum Current per Output 1,15 A
Maximum Total Electric Power 500W (distributed over 8 outputs).
Electrical Efficiency > 92% with maximum output power.
Overcurrent Protection Is ≥ 1.5 A at each output (automatic return when the current drops to the maximum rated value)).
Short Circuit Protection By limiting the output current
Voltage Surge Protection At inputs and outputs.
Overheat protection Outputs shutdown
Electrical Connections Through a 3-way connector at the input and 8×2 ways at the outputs with screws (Cable up to 12AWG)
Optical Connections MPO adapter at the input and SC / APC at 8 outputs
Light indication 8 LEDs on the PSE Unit panel (one per output) indicate the operation of the respective output: on = ok / off = failure.
Grounding Accessible on the primary source power connector.

Maximum electric power available per PDU port: 62W

Below the electric power consumption values, considering the Furukawa POE ONTs models:

ONTs Electric power consumed Electric power available for charge
LW110-20BP 10 W 52 W
LW710-40BP 9,3 W 52,7 W
LW510-40BP 12 W 50 W
LW710-80BP 9,3 W 52,7 W

Installation Environment

In cabinet (DIN rail) or cable tray

Operation Temperature (ºC)

0 to + 40 ° C

Forced ventilation, through 2 fans

Cross Section

Imagem adicionada pelo usuárioImagem adicionada pelo usuárioImagem adicionada pelo usuárioImagem adicionada pelo usuário

 

Notas1

The PDU-Laserway does not come with a power cord included.

  • For the AC PDU model, the power cords that can be used are:

                 35510161 – POWER CORD STANDARD NBR 14136 / IEC C13

                 35510251 – POWER CORD NEMA 5-15P / IEC C13 STANDARD

                 35510250 – POWER CORD STANDARD IRAM ARG302 / IEC C13 

                 35510896 – POWER CORD STANDARD CY EU PLUG (2 PINOS) / IEC C13 

  • For the DC PDU model, it is necessary to check the rectifier source connection.