Home chevron_right Products chevron_right Optical Cables chevron_right Indoor Cables chevron_right OPTICAL CABLE FIBER-LAN INDOOR 06F MM (50) OM3 LSZH AQ – EUROCLASS Dca (s1,d2,a1)
Descontinuado
Code - 26272056

OPTICAL CABLE FIBER-LAN INDOOR 06F MM (50) OM3 LSZH AQ – EUROCLASS Dca (s1,d2,a1)

Internal optical cable with 2 up to 72 singlemode or multimode optical fibers arranged in "tight" design. Optical fibers are coated with acrylate resin and a secondary coating of colored thermoplastic material. Dielectric strength members surround the set of fibers and a thermoplastic flame-retardant outer jacket covers it.

Internal optical cable with 2 up to 72 singlemode or multimode optical fibers arranged in "tight" design. Optical fibers are coated with acrylate resin and a secondary coating of colored thermoplastic material. Dielectric strength members surround the set of fibers and a thermoplastic flame-retardant outer jacket covers it.

Construction

RoHS-2 Compliant
Dielectric
Tight Buffer
Singlemode or Multimode

Description

Optical cable with singlemode or multimode optical fibers arranged in "tight" design. Optical fibers are coated with acrylate resin and a secondary coating of thermoplastic material. Dielectric strength members surround the set of fibers and a thermoplastic flame-retardant outer jacket covers it.

Application

Installation Environment Indoor
Operation Environment Installation in ducts and connection between entrance rooms

Standard

  • ITU-T G.651: "Characteristics of a 50/125 μm multimode graded index optical fibre and cable"
  • ITU-T G.652: "Characteristics of a single-mode optical fibre and cable"
  • Telcordia GR-409: "Generic requirements for indoor fiber optic cable"
  • ANSI/TIA-568.3-D: "Optical fiber cabling components standard".
  • EN 60332-1-2: “Tests on electric and optical fibre cables under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable – Procedure for 1 kW pre-mixed flame”;
  • EN 61034-2: “Measurement of smoke density of cables burning under defined conditions – Part 2: Test procedure and requirements”;
  • EN 50399: "Common test method for cables under fire conditions. Heat release and smoke production measurement on cables during flame spread test. Test apparatus, procedures, results";
  •  EN 50267-2-3: "Common test method for cables under fire conditions. Test on gases evolved during combustion of materials from cables. Procedures. Determination of degree of acidity of gases for cables by determination of the weighted average of pH and conductivity";
  • IEC 61034-2:  Measurement of smoke density of cables burning under defined conditions; Part 2: Test procedure and requirements;
  • IEC 60794-1-22: Optical fibre cables – Part 1-22: Generic Specification – Basic optical cable test procedures – Environmentar test methods;
  • IEC 60794-1-21: Optical fibre cables – Part 1-21: Generic Specification – Basic optical cable test procedures – Mechanical test methods;
  • TIA-492AAAD: Detail Specification for 850nm laser-optimized, 50um core diameter/125um cadding diameter class la Granded-index Multimode Optical fibers suitable for manufacturing OM4 cabled optical fiber;
  • TIA-492AAAC: Detail Specification for 850nm laser-optimized, 50um core diameter/125um cadding diameter class la Granded-index Multimode Optical fibers suitable for manufacturing OM3 cabled optical fiber.

Standard Requeriment Limit
EN 50399 Total Heat Realese ≤ 70MJ
Peak Heat Release Rate  ≤ 40kW
Fire Index Growth Rate ≤ 1300 W/s
EN 60332-1-2 Height ≤ 425 mm

Certifications

ETL (OFNR) Listed – Report N°: 100824709CRT-001

ETL (DMD) – Report N°: 3174638CRT-001

Euroclass: Dca (s1a, d2, a1)

Optical Fiber

SM (Singlemode), MM (Multimode) OM3 and OM4.

Optical Characteristics

Fiber Characteristics
Single mode According to technical specification 2000 (Annex A)
Multi mode (OM3 and OM4) According to technical specification 1999 (Annex B)

G652.D
OM3 OM4
Maximum
Cabled fiber attenuation
0.8 dB/km @1310nm
0.6 dB/km @1550nm
2.3dB/km @850nm
0.6 db/km @1300nm
2.3 dB/km @850nm
0.6 dB/km @1300nm
Typical
cabled fiber attenuation
0.36 dB/km @1310nm
0.36 dB/km @1383nm
0.22 dB/km @1550nm
0.35 dB/km @1625nm

Fiber Coating

Optical fiber with an acrylate coating.

Fiber Identification

Fiber

Color

01

Blue

02

Orange

03

Green

04

Brown

05

Gray

06

White

07

Red

08

Black

09

Yellow

10

Violet

11

Pink

12

Acqua

Core

Fiber Count

Sub-units Count

2 a 12