Mainly used in Duct-Installation (HD-PE Tubes) and installed by Cable Blowing or Pulling
Loose Tube Fibre Optic Outdoor Cable 8 Element All Dielectric Dry Core Design Standard Duct TT
Loose Tube Fibre Optic Outdoor Cable 8 Element All Dielectric Dry Core Design Standard Duct TT
Mainly used in Duct-Installation (HD-PE Tubes) and installed by Cable Blowing or Pulling
Version illustrated is the 96 Fiber Cable
Product Specification | ||||||
---|---|---|---|---|---|---|
Fiber Count | Tubes | Core Design | Outer Diameter [mm] | Cable Weight [kg/km] | Standard Length [m] | AT-Code** |
84 | 7 (12F) | 1+8 (1Filler*) | 11.0 | 100 | 2000 / 4000 / 6000 / 8000 | AT-[][][]12UT-084-TT |
96 | 8 (12F) | 1+8 | 11.0 | 100 | 2000 / 4000 / 6000 / 8000 | AT-[][][]12UT-096-TT |
This table shows nominal diameter and weight values which may differ in shipments. *Fillers are natural colored. **Please refer to the LIGHTERA AT- Code. The blanks specify the fiber type. |
Identification Tube and Fiber Color Code | |
---|---|
1 | Blue |
2 | Orange |
3 | Green |
4 | Brown |
5 | Grey |
6 | White |
7 | Red |
8 | Black |
9 | Yellow |
10 | Violet |
11 | Rose |
12 | Aqua |
Note | Alternative tube and fiber color code available on request |
Sheath Marking |
---|
OFS OPTICAL CABLE STANDARD DUCT-TT [ID] [MM/YYYY] [Handset Sign] xxxF [Meter Marking] |
Alternative sheath printing available on request. In case of order the exact sheath printing text will be clarified with the customer. |
Mechanical Properties and Environmental Behavior | |||
---|---|---|---|
Tests according to IEC 60794 | |||
Parameter | Requirement | Value | |
Tensile Performance: IEC 60794-1-21-E1 |
Long term load | – No attenuation increase* – No fiber strain |
Load: 2000 N |
Short term load, during installation | – No changes in attenuation before versus after load – Max. fiber strain 0.6% |
Load: 4000 N | |
Crush Performance: IEC 60794-1-21-E3A |
Long term load | – No attenuation increase* | Load (Plate / Plate): 750 N |
Short term load | – No changes in attenuation before versus after load – No damage** |
Load (Plate / Plate): 4500 N | |
Impact Performance: IEC 60794-1-21-E4 |
3 Impacts; 500 mm apart Anvil: R = 300 mm |
– No changes in attenuation before versus after load – No damage** |
Energy: 5 J |
Bending Performance: IEC 60794-1-21-E11 |
Handling fixed installed | – No attenuation increase* | Bend radius: 10 X D |
During installation (under load) | – No changes in attenuation before versus after load | Bend radius: 20 X D, D is the cable diameter | |
Temperature Performance: IEC 60794-1-22-F1 |
Operation Installation Storage/Shipping |
– No attenuation increase* | -40 to +70°C -15 to +60°C -40 to +70°C |
* No changes in attenuation means that any changes in measurement value, either positive or negative within the uncertainty of measurement shall be ignored. The total uncertainty of measurement shall be less than of equal to 0.05 dB. ** Mechanical damage – when examined visually without magnification, there shall be no evidence of damage to the sheath. The imprint of plates will not be considered as damage. |
Shipping Information | |||
---|---|---|---|
Cable Length | Drum Diameter | Drum Width | Shipping Weight (calc.) Drum + Cable |
2000 m | 1000 mm | 780 mm | 250 kg |
4000 m | 1400 mm | 780 mm | 490 kg |
6000 m | 1550 mm | 1060 mm | 730 kg |
8000 m | 1550 mm | 1060 mm | 930 kg |
The shipping information are given for one-way reels. Reusable reels are available on request. |
The information is believed to be accurate at time of issue.
Lightera reserves the right to make changes to the product(s) described in this document at any time without notice. This document is for informational purposes only and is not intended to modify or supplement any Lightera warranties or specifications relating to any of its products or services.
Compare features, sizes, models to find the perfect option for you
This section is under construction. To view our products, please select below.