| Applicable Fibers *¹ |
SM (ITU-T G.652 / G.657A1 / G.657A2) MM (ITU-T G.651) DS (ITU-T G.653) NZD (ITU-T G.655) BIF (ITU-T G.657.A1/A2) |
| Fiber Count |
Up to 12-fibers |
| Cladding Diameter |
125µm |
| Fiber Coating Diameter Single Fiber |
0.25mm, 0.9mm |
| Fiber Coating Diameter Ribbon Fiber |
Refer to Fiber Holder |
| Fiber Cleaving Length |
10mm |
| Average Splice Loss *² |
SM 0.05dB MM 0.03dB; DS 0.08dB NZD 0.08dB BIF 0.05dB |
| Typical Splice Time |
12-fiber ribbon 15sec. Single fiber 13sec. |
| Typical Heating Time |
12-fiber ribbon : 28sec. (S927R, power mode) 8-fiber ribbon 14sec. (S924, power mode) Single fiber 13sec (S921, power mode) |
| Splice Program |
Max. 300 |
| Heat Program |
Max. 100 |
| Applicable Protection Sleeve Length |
40mm / 60mm |
| Tension Test |
1.96N |
| Discharge compensation function |
Automatic correction according to temperature and atmospheric pressure |
| Optical Fiber Viewing Method |
Two-way observation from X and Y axes |
| Monitor |
4.3 inch wide LCD monitor with touch screen |
| Magnification |
20X, 28X (in zooming), 56X (in zooming) |
| Splice Result Storage |
Last 10,000 splices |
| Image Capture Capacity |
Last 100 images to be automatically captured |
| Dimensions |
139W x 209D x 114H mm not including shock absorber 179W X 246D X 131H mm including shock absorber |
| Weight |
1.8kg (with battery) |
| Data Output |
USB ver.2 mini B X 1 port, Standard A X 1 port |
| Power Source |
AC 100-240V (50/60Hz) DC 11-24V |
| Battery Capacity* |
170 splice and heating cycles |
| Operating Condition |
Altitude : 0-2,000m Wind protection : 15m/s Operating temperature : -10 to +50 °C (non-condensing) |
| Storage Condition |
-40 to +60 °C (non-condensing) |
| Note |
*1 Corresponding to optical fiber in compliance with ITU-T recommendation. |
| Note |
*2 This numerical number is the one when measured for the purpose to show the fusion splice characteristics in the testing method of IEC 61073-1, it is not the one to guarantee the splicing loss. |
| Note |
*3 Number of times that the fusion splicing of the fiber and the heat reinforcement can be performed continuously at a rate of once a 90seconds at the room temperature (20°C) condition when using a new 100% charged battery. The number of times you can use depends on the state of the battery and usage. |