The AccuTube+ Rollable Ribbon (RR) Cable features 432, 576, 864, or 1728 optical fibers in a gel‐free, loose tube cable design. This cable features rollable ribbons, Lightera’ newest optical fiber ribbon design. To form these ribbons, individual 250 µm fibers are partially bonded to each other at predetermined points.
The AccuTube+ Rollable Ribbon (RR) Cable features 432, 576, 864, or 1728 optical fibers in a gel‐free, loose tube cable design. This cable features rollable ribbons, Lightera’ newest optical fiber ribbon design. To form these ribbons, individual 250 µm fibers are partially bonded to each other at predetermined points.
The AccuTube+ Rollable Ribbon (RR) Cable features 432, 576, 864, or 1728 optical fibers in a gel‐free, loose tube cable design. This cable features rollable ribbons, Lightera’ newest optical fiber ribbon design. To form these ribbons, individual 250 µm fibers are partially bonded to each other at predetermined points.
With up to 1728 fibers in a single cable, the AccuTube+ RR Cable offers exceptional carrying capacity for high-growth, high-bandwidth applications. This cable’s rollable ribbon design helps users achieve highly efficient and cost-effective mass fusion splicing along with easy individual fiber breakout. This capability helps to simplify installation and save on labor costs. In addition, the AccuTube+ RR Cable’s significantly greater fiber density can help to expand the capacity of existing pathways using smaller, lower-cost duct systems. For example, the 1728 fiber count cables can be routed in existing 1 1/4-inch pathways while the 3456 fiber count cables are suited for 2-inch pathways.
The AccuTube+ RR Cable’s ribbons may be “rolled” (compacted) and routed like individual fibers to facilitate use in smaller closures and splice trays.
In addition, this cable’s completely gel-free water-blocking design also helps to reduce the time required to prepare cable ends and achieve mid-span access which can also help with reduced labor and splice costs.
With its ability to maximize duct utilization, the AccuTube+ RR Cable is an excellent choice for connecting very large fiber distribution hubs. It is also highly suitable for use in data centers, FTTx and access networks.
Specifications | |||
---|---|---|---|
Dielectric Construction |
|||
Fiber Count | 432 |
576-864 |
1728 |
Cable Outer Diameter – In. (mm) | 0,66 (16.8) | 0.85 (21.6) | 0.99 (25.1) |
Cable Weight – Lb/kft (kg/km) | 141 (210) | 212 (315) | 310 (460) |
Buffer Tube Diameter In. (mm) | 0.18 (4.5) | 0.24 (6.0) | 0.28 (7.0) |
Recommended Duct Size | 1 in. | 1 in. | 1 1/4 in. |
Metallic Construction |
|||
Fiber Count | 432 |
576-864 |
1728 |
Cable Outer Diameter – In. (mm) | 0.73 (18.6) | 0.91 (23.2) | 1.05 (26.8) |
Cable Weight – Lb/kft (kg/km) | 195 (290) | 281 (418) | 366 (545) |
Buffer Tube Diameter In. (mm) | 0.18 (4.5) | 0.24 (6.0) | 0.30 (7.0) |
Recommended Duct Size | 1 in. | 1 1/4 in. | 1 1/2 in. |
Handling | |
---|---|
Minimum Bend Radius, with Load | 15 OD (Outer Diameter) |
Minimum Bend Radius, with No Load | 15 X OD |
Minimum Bend Radius, Storage Coils | 15 X OD |
Rated Installation Load | 1000 lb. (4448 N) |
Maximum Long-term Load | 333 lb. (1481 N) |
Temperature | |
---|---|
Installation | -22 °F to 140 °F (-30 °C to 60 °C) |
Operation | -40 °F to 158 °F (-40 to 70 °C) |
Storage | -40 °F to 167 °F(-40 °C to 75 °C) |