Optimized for Aerial- and Duct Installation with fiber counts up to 72 fibers
All-Dielectric, Self Supporting (ADSS) Aerial Loose Tube Fiber Optic Cable Dry core design PowerGuide® SkyLight
All-Dielectric, Self Supporting (ADSS) Aerial Loose Tube Fiber Optic Cable Dry core design PowerGuide® SkyLight
Optimized for Aerial- and Duct Installation with fiber counts up to 72 fibers
Version illustrated is the 72 Fiber 6 Element Cable
| Product Specification | |||||
|---|---|---|---|---|---|
| Fiber Count | Tubes | Core Design | Outer Diameter [mm] | Cable Weight [kg/km] | AT-Code** |
| 12 | 1 (12F) | 1+6 (5 Fillers*) | 10.4 | 90 | AT-[ ][ ][ ]17UT-012-CNGA |
| 24 | 2 (12F) | 1+6 (4 Fillers*) | 10.4 | 90 | AT-[ ][ ][ ]17UT-024-CNGA |
| 36 | 3 (12F) | 1+6 (3 Fillers*) | 10.4 | 90 | AT-[ ][ ][ ]17UT-036-CNGA |
| 48 | 4 (12F) | 1+6 (2 Fillers*) | 10.4 | 90 | AT-[ ][ ][ ]17UT-048-CNGA |
| 60 | 5 (12F) | 1+6 (1 Filler*) | 10.4 | 90 | AT-[ ][ ][ ]17UT-060-CNGA |
| 72 | 6 (12F) | 1+6 | 10.4 | 90 | AT-[ ][ ][ ]17UT-072-CNGA |
| This table shows nominal diameter and weight values which may differ in shipments. *Fillers are natural colored. **Please refer to the LIGHTERA AT- Code. The blanks specify the fiber type. |
|||||
| Identification Tube and Fiber Color Code | |
|---|---|
| 1 | Blue |
| 2 | Orange |
| 3 | Green |
| 4 | Brown |
| 5 | Grey |
| 6 | White |
| 7 | Red |
| 8 | Black |
| 9 | Yellow |
| 10 | Violet |
| 11 | Pink |
| 12 | Aqua |
| Note | Alternative tube and fiber color code available on request. |
| Sheath Marking |
|---|
| Lightera OPTICAL ADSS CABLE [ID] [MM/YYYY] [Handset Sign] xxxF [Meter Marking] Alternative sheath printing available on request. In case of order the exact sheath printing text will be clarified with the customer. |
| Shipping Information | |||
|---|---|---|---|
| Cable Length | Drum Diameter | Drum Width | Shipping Weight (calc.) Cable + Drum |
| 2 Km | 1000 mm | 780 mm | 230 Kg |
| 4 Km | 1400 mm | 780 mm | 450 Kg |
| 6 Km | 1550 mm | 1060 mm | 670 Kg |
| 8 Km | 1550 mm | 1060 mm | 850 Kg |
| The shipping information are given for one-way reels. Reusable reels are available on request. | |||
| Temperatures (IEC 60794-1-22-F1) | |
|---|---|
| Operation | -40°C to +70°C |
| Installation | -15°C to +60°C |
| Storage/shipping | -40°C to +70°C |
| Sag and Tension Calculation AT-[][][]17UT-072-CNGA | |||
|---|---|---|---|
| Conditions | NESC Light Loading | NESC Medium Loading | NESC Heavy Loading |
| Ice Thickness | 0 mm | 6.4 mm | 12.7 mm |
| Wind Pressure | 431 N/m² (95.5 km/h) | 192 N/m² (63.6 km/h) | 192 N/m² (63.6 km/h) |
| Low Temperature | -1 °C | -9.4 °C | -17.8 °C |
| Safety Factor | 0.73 N/m | 2.92 N/m | 4.38 N/m |
| Tension @ Maximum Span for 1,0 % Installation Sag | |||
| Maximum Span | 150 m | 100 m | 60 m |
| MRCL (Maximum Rated Cable Load) | 3500 N | 3500 N | 3500 N |
| MIT (Maximum Installation Tension) | 1500 N | 950 N | 550 N |
| Installation Temperature | 23 °C | 23 °C | 23 °C |
| Cable Modulus | 940.3 kg/mm² | 940.3 kg/mm² | 940.3 kg/mm² |
| CTE (C-1) | 1.24E- 05 | 1.24E- 05 | 1.24E- 05 |
| Recommended Hardware For Spans Up to 150m | |
|---|---|
| PLP: | |
| Dead End Assembly: |
FIBERLIGN® Dielectric Dead-end for ADSS, 2872001C1E1, Max. Tension: 2500 lbs. (1135 kg) |
| Fixed Tangent Support: |
FIBERLIGN® Aluminum Support for ADSS, 4450098 |
| Suspended Support: |
FIBERLIGN® Aluminum Suspension for ADSS, 4450198 |
| Slack Storage Devices: |
FIBERLIGN® In-Span Storage System, FIS12A |
| Down Lead Cushion: |
FIBERLIGN® Downlead Cushion for ADSS, 8003041 |
| Vibration Dampers: |
FIBERLIGN® Dielectric Damper for ADSS Cable, 50502272 |
| Telenco: |
|
| Dead End Assembly: |
TELENCO® GSDE AR Helical dead-ends with armor rods Model GSDE AR 1050 (PN 7640) |
| Vibration Dampers: |
TELENCO® Vibration damper VIB Model VIB083 (PN 09139) |
| Suspension Support: |
TELENCO® DSAL Mobile suspension clamp Model DSAL1000 (PN 09567) |
Optimized for Aerial- and Duct Installation with fiber counts up to 72 fibers
Version illustrated is the 72 Fiber 6 Element Cable
| Product Specification | |||||
|---|---|---|---|---|---|
| Fiber Count | Tubes | Core Design | Outer Diameter [mm] | Cable Weight [kg/km] | AT-Code** |
| 12 | 1 (12F) | 1+6 (5 Fillers*) | 10.4 | 90 | AT-[ ][ ][ ]17UT-012-CNGA |
| 24 | 2 (12F) | 1+6 (4 Fillers*) | 10.4 | 90 | AT-[ ][ ][ ]17UT-024-CNGA |
| 36 | 3 (12F) | 1+6 (3 Fillers*) | 10.4 | 90 | AT-[ ][ ][ ]17UT-036-CNGA |
| 48 | 4 (12F) | 1+6 (2 Fillers*) | 10.4 | 90 | AT-[ ][ ][ ]17UT-048-CNGA |
| 60 | 5 (12F) | 1+6 (1 Filler*) | 10.4 | 90 | AT-[ ][ ][ ]17UT-060-CNGA |
| 72 | 6 (12F) | 1+6 | 10.4 | 90 | AT-[ ][ ][ ]17UT-072-CNGA |
| This table shows nominal diameter and weight values which may differ in shipments. *Fillers are natural colored. **Please refer to the LIGHTERA AT- Code. The blanks specify the fiber type. |
|||||
| Identification Tube and Fiber Color Code | |
|---|---|
| 1 | Blue |
| 2 | Orange |
| 3 | Green |
| 4 | Brown |
| 5 | Grey |
| 6 | White |
| 7 | Red |
| 8 | Black |
| 9 | Yellow |
| 10 | Violet |
| 11 | Pink |
| 12 | Aqua |
| Note | Alternative tube and fiber color code available on request. |
| Sheath Marking |
|---|
| Lightera OPTICAL ADSS CABLE [ID] [MM/YYYY] [Handset Sign] xxxF [Meter Marking] Alternative sheath printing available on request. In case of order the exact sheath printing text will be clarified with the customer. |
| Shipping Information | |||
|---|---|---|---|
| Cable Length | Drum Diameter | Drum Width | Shipping Weight (calc.) Cable + Drum |
| 2 Km | 1000 mm | 780 mm | 230 Kg |
| 4 Km | 1400 mm | 780 mm | 450 Kg |
| 6 Km | 1550 mm | 1060 mm | 670 Kg |
| 8 Km | 1550 mm | 1060 mm | 850 Kg |
| The shipping information are given for one-way reels. Reusable reels are available on request. | |||
| Temperatures (IEC 60794-1-22-F1) | |
|---|---|
| Operation | -40°C to +70°C |
| Installation | -15°C to +60°C |
| Storage/shipping | -40°C to +70°C |
| Sag and Tension Calculation AT-[][][]17UT-072-CNGA | |||
|---|---|---|---|
| Conditions | NESC Light Loading | NESC Medium Loading | NESC Heavy Loading |
| Ice Thickness | 0 mm | 6.4 mm | 12.7 mm |
| Wind Pressure | 431 N/m² (95.5 km/h) | 192 N/m² (63.6 km/h) | 192 N/m² (63.6 km/h) |
| Low Temperature | -1 °C | -9.4 °C | -17.8 °C |
| Safety Factor | 0.73 N/m | 2.92 N/m | 4.38 N/m |
| Tension @ Maximum Span for 1,0 % Installation Sag | |||
| Maximum Span | 150 m | 100 m | 60 m |
| MRCL (Maximum Rated Cable Load) | 3500 N | 3500 N | 3500 N |
| MIT (Maximum Installation Tension) | 1500 N | 950 N | 550 N |
| Installation Temperature | 23 °C | 23 °C | 23 °C |
| Cable Modulus | 940.3 kg/mm² | 940.3 kg/mm² | 940.3 kg/mm² |
| CTE (C-1) | 1.24E- 05 | 1.24E- 05 | 1.24E- 05 |
| Recommended Hardware For Spans Up to 150m | |
|---|---|
| PLP: | |
| Dead End Assembly: |
FIBERLIGN® Dielectric Dead-end for ADSS, 2872001C1E1, Max. Tension: 2500 lbs. (1135 kg) |
| Fixed Tangent Support: |
FIBERLIGN® Aluminum Support for ADSS, 4450098 |
| Suspended Support: |
FIBERLIGN® Aluminum Suspension for ADSS, 4450198 |
| Slack Storage Devices: |
FIBERLIGN® In-Span Storage System, FIS12A |
| Down Lead Cushion: |
FIBERLIGN® Downlead Cushion for ADSS, 8003041 |
| Vibration Dampers: |
FIBERLIGN® Dielectric Damper for ADSS Cable, 50502272 |
| Telenco: |
|
| Dead End Assembly: |
TELENCO® GSDE AR Helical dead-ends with armor rods Model GSDE AR 1050 (PN 7640) |
| Vibration Dampers: |
TELENCO® Vibration damper VIB Model VIB083 (PN 09139) |
| Suspension Support: |
TELENCO® DSAL Mobile suspension clamp Model DSAL1000 (PN 09567) |
Compare features, sizes, models to find the perfect option for you