Whether your fiber optic cables are located in a Controlled Environmental Vault (CEV) or a remote site location, you need to be able to get to them easily. And when you do, you must be confident that they have remained secure, just the way you left them — safe from unauthorized personnel. The Lightera 400A Fiber Optic Interface Unit, provides both easy access and security.
Developed by Lightera Labs, the 400A interface unit is a modular enclosure that provides cross-connect and interconnect capabilities for splicing and terminating Outside Plant Cables (OSP) or Fiber Optic Building Cables.
As shown below, the 400A interface unit has two separate side-by-side sections. One side houses terminated fibers; the other side houses organized jumpers. Each side has its own door with different keys. Although the unit comes in two models (400 A1 and 400 A2), the models are essentially identical. However, for greater security, Model 400A-2 has locks installed on each door.
Whether your fiber optic cables are located in a Controlled Environmental Vault (CEV) or a remote site location, you need to be able to get to them easily. And when you do, you must be confident that they have remained secure, just the way you left them — safe from unauthorized personnel. The Lightera 400A Fiber Optic Interface Unit, provides both easy access and security.
Developed by Lightera Labs, the 400A interface unit is a modular enclosure that provides cross-connect and interconnect capabilities for splicing and terminating Outside Plant Cables (OSP) or Fiber Optic Building Cables.
As shown below, the 400A interface unit has two separate side-by-side sections. One side houses terminated fibers; the other side houses organized jumpers. Each side has its own door with different keys. Although the unit comes in two models (400 A1 and 400 A2), the models are essentially identical. However, for greater security, Model 400A-2 has locks installed on each door.
Because of its security features and flexible design, our interface unit is currently being used in a number of applications, for example:
Whether your fiber optic cables are located in a Controlled Environmental Vault (CEV) or a remote site location, you need to be able to get to them easily. And when you do, you must be confident that they have remained secure, just the way you left them — safe from unauthorized personnel. The Lightera 400A Fiber Optic Interface Unit, provides both easy access and security.
Developed by Lightera Labs, the 400A interface unit is a modular enclosure that provides cross-connect and interconnect capabilities for splicing and terminating Outside Plant Cables (OSP) or Fiber Optic Building Cables.
As shown below, the 400A interface unit has two separate side-by-side sections. One side houses terminated fibers; the other side houses organized jumpers. Each side has its own door with different keys. Although the unit comes in two models (400 A1 and 400 A2), the models are essentially identical. However, for greater security, Model 400A-2 has locks installed on each door.
The 12A1 Cable Clamp is designed to provide means of securing one OSP cable inside the 400A interface unit. The clamp provides grounding for either ribbon cable equipped with sheath terminating hardware or stranded cable with metallic strength members. The 12A1 consists of a mounting bracket, plastic clamps, and suitable grounding lugs. It is recommended that two (2) 12A1s be installed inside the unit.
Clamp is similar to the 12A1 Clamp, but used with nonmetallic OSP cables.
The panel can be mounted in either a 19 inch (48.26 cm) or 23 inch (58.42 cm) frame and gives the user the capabilities to install one (1) 400A interface unit in a standalone, interconnection or cross-connection configuration.
This panel is an ideal panel to use when wall space is limited and frame space is available. It comes equipped with mounting screws, nuts and 742A mounting screws.
This kit of parts is used to prepare OSP cable for direct termination of connectors in the 400A interface unit. It includes cable end prep materials and individual fiber protective buffer tubing.
Order fanout for use with the 400A units. The fanout provides an easy transition from array connectorized ribbon cable to 12 individual fibers at the termination panels. Order fanouts with a 400A unit to provide easy transition from ribbon based cable to 12 individual connectors.
The standard fanout consists of an array of connectorized ribbon which transitions into 12 individual, connectorized fibers.
Splice kits are available in mass, single, or mechanical splicing configurations to expedite installation methods. Choose the desired splice kit for the first tray of splice organizers, then increase splicing count with additional supplemental trays.
|
400A LIU Termination Chart |
||
|---|---|---|
|
400A LIU Termination Chart – Mechanical |
||
| Number of Trays | Mechanical Splices | Adapter Ports |
|
0 |
0 |
96 LC, 48 SC, 48 ST |
|
1 |
12 |
96 LC, 48 SC, 48 ST |
|
2 |
24 |
80 LC, 40 SC, 40 ST |
|
3 |
36 |
64 LC, 32 SC, 32 ST |
|
400A LIU Termination Chart – Single Fusion |
||
| Number of Trays | Single Fusion Splices | Adapter Ports |
|
0 |
0 |
96 LC, 48 SC, 48 ST |
|
1 |
16 |
96 LC, 48 SC, 48 ST |
|
2 |
32 |
80 LC, 40 SC, 40 ST |
|
3 |
48 |
64 LC, 32 SC, 32 ST |
|
400A LIU Termination Chart – Mass Fusion |
||
| Number of Trays | Mass Fusion Splices | Adapter Ports |
|
0 |
0 |
96 LC, 48 SC, 48 ST |
|
1 |
6 (72) |
96 LC, 48 SC, 48 ST |
|
2 |
12 (144) |
80 LC, 40 SC, 40 ST |
|
3 |
18 (216) |
64 LC, 32 SC, 32 ST |
When installing a cross-connect or interconnect configuration with top- entry cables, the recommended growth pattern is to install the first 400A interface unit at the top left corner of the allocated space. Any additional units should be placed beneath the first unit to create a column of up to five modules high.
The number of units per column depends on the vertical dimension of the allocated space. The top of the highest module should not exceed 68 inches (172.72 cm) from the floor.
The 400A Fiber Optic Interface Unit combines the latest in fiber optic technology with the latest in cabinet design. The space saving features and modular design of these units provide the flexibility you need for future growth — without the expense of replacing existing equipment. When you choose the 400A Fiber Optic interface unit from Lightera, you get optimum equipment at minimum cost. It’s another one of Lightera Labs innovations — keeping your network on the cutting-edge of fiber optic technology.
|
Ordering Information – Splice Kits (100, 200, and 400 LIU) |
||
|---|---|---|
| Product Code | Description | Comcode |
|
Kit LG-D181706 |
LIU Mechanical Splice Kit Base Unit, has 1 Sup Tray |
108 915 141 |
|
Supplemental Mech. Splice Kit |
LIU Supplemental tray and organizer |
108 915 364 |
|
1 AM1-12 LG Organizer |
Mechanical Organizer (12 mechanicals) part of Sup Tray (pack of 10) |
105 356 570 |
|
Kit LG-D181707 |
LIU Single Splice Kit Base Unit, has 1 Sup Tray |
108 915 166 |
|
Supplemental Fusion Splice Kit |
LIU Supplemental Tray and Organizer |
108 915 356 |
|
1 AF1-16 LG Organizer |
Single Fusion Organizer (16 fusion) part of Sup Tray (pack of 10) |
105 356 562 |
|
Kit, Mass Fusion Splice |
LIU Mass Splice Kit Base Unit, has 1 Sup Tray |
300 386 976 |
|
Kit, Supplemental Fusion Splice |
LIU Supplemental tray and organizer |
300 386 984 |
|
Splice Holder, LG. Mass Fusion |
Mass Fusion Organizer (6 Mass fusion) fits Sup Tray (pack of 12) |
109 116 046 |
|
LIU Box Accessories |
||
| Product Code | Description | Comcode |
|
742 A Panel |
100, 200, 400 Frame Mounting Panel |
108 915 182 |
|
Holder-1A1 Lightguide |
100, 200, 400 LIU Mini fanout holder for inside box |
108 919 283 |
|
Basic Cabinet |
||
| Product Code | Description | Comcode |
|
400 A1 Fiber Optic Interface Unit (w/o Locks) |
108 905 662 |
|
|
400 A2 Fiber Optic Interface Unit (with 2 Locks) |
108 905 670 |
|
|
7-inch Panels Used on 400 LIU Panels Pre-Loaded with Adapters |
||
| Product Code | Adapter Capacity | Comcode |
|
1000LC1W-SMPL-E/W |
6 LC Simplex Adapters |
108 597 519 |
|
1000LC1W-DPL-E/W |
6 LC Duplex Adapters |
108 597 527 |
|
1000LCA1W-DPL-E/W |
6 Angled LC Duplex Adapters |
108 610 858 |
|
1000LCA1W-SMPL-E/W |
6 Angled LC Simplex Adapters |
108 610 908 |
|
F91AK8515 ASSY |
6 SC Adapters for MM or SM Use |
106 500 630 |
|
F91AK8514 ASSY |
6 SM ST Adapters |
106 500 622 |
|
1000ST-C2000A-2 |
6 MM ST Adapters |
107 802 498 |
|
MWK-6 |
6 FC adapters |
106 225 923 |
|
Ordering Information (Continued) |
|||
|---|---|---|---|
|
7-inch Panels Used on 400 LIU Panels with Adapter Cutouts Only (No Adapters) |
|||
| Product Code | Cutout Capacity | Comcode | Reference Adapters (note) |
|
1000LC1-SMPLX-6 |
6 LC Simplex Adapter Cutouts |
108 365 685 |
SM C1101A-1 107 764 268 |
|
1000LC1-DPLX |
6 LC Duplex Adapter Cutouts |
108 365 693 |
MM C1001B-2 108 072 497 or SM C1101A-2 108 072 489 |
|
1000SC1 LG |
3 SC Duplex Adapter Cutouts |
106 372 121 |
SM/MM-C6000A-5 107 022 980 |
|
CONNLG-1000ST |
6 ST Adapter Cutouts |
105 392 005 |
SM-C3000A2 105 271 142 |
|
CONNLG-1000ST LO |
12 Pack of 6 ST Adapter Cutouts |
105 428 486 |
MM-C2000A2 104 148 028 or SM-C3000A2 105 271 142 |
|
CONNLG-1000FC/D4 |
6 FC/D4 Adapter Cutouts |
105 428 254 |
– |
|
1000BK |
Blank Panel (Package of 6) |
106 924 483 |
– |
|
These panels do not come equipped with adapters. To order the proper adapters for use with the panel, use the adapters listed in the Reference Adapters column that are associated with the ordered panel. |
|||
For additional information please contact your sales representative. You can also visit our website at www.lightera.com or call 1-888-FIBERHELP (1-888-342-3743) USA or 1-770-798-5555 outside the USA. For a full list of our certifications, visit our website.
Lightera reserves the right to make changes to the product(s) described in this document at any time without notice. This document is for informational purposes only and is not intended to modify or supplement any Lightera warranties or specifications relating to any of its products or services.
Compare features, sizes, models to find the perfect option for you