- Low splice loss
- Clamp Soft-Landing
- Compact size
- Portability by built-in battery (Optional)
- Easy operation by LCD screen with touch panel
- Fiber clamp can be detached from canopy
- Remote control by Wi‑Fi communication
The FITEL S185LDF / S185PMLDF High‑end Fusion Splicers are designed for splicing up to 500μm cladding fiber or 500m PM fiber with low splice loss. The powerful and compact design has been optimized for the Fiber laser industry. The new fiber alignment mechanism achieves low splice loss. The new design also allows the fiber clamps to close gently to reduce the possibility of damage to the fiber. Battery operation and a compact design make transporting the LDF Fusion Splicer easy.
The FITEL S185LDF / S185PMLDF High‑end Fusion Splicers are designed for splicing up to 500μm cladding fiber or 500m PM fiber with low splice loss. The powerful and compact design has been optimized for the Fiber laser industry. The new fiber alignment mechanism achieves low splice loss. The new design also allows the fiber clamps to close gently to reduce the possibility of damage to the fiber. Battery operation and a compact design make transporting the LDF Fusion Splicer easy.
The FITEL S185LDF / S185PMLDF High‑end Fusion Splicers are designed for splicing up to 500μm cladding fiber or 500m PM fiber with low splice loss. The powerful and compact design has been optimized for the Fiber laser industry. The new fiber alignment mechanism achieves low splice loss. The new design also allows the fiber clamps to close gently to reduce the possibility of damage to the fiber. Battery operation and a compact design make transporting the LDF Fusion Splicer easy.
| Specification | |||||
|---|---|---|---|---|---|
| Description | S185LDF | S185PMLDF | |||
| Applicable Fibers*¹ | SM, MM, DS, NZDS, High-Index, EDF, LDF | SM, MM, DS, NZDS, High-Index, EDF, PMF | |||
| Cladding Diameter | 125 to 500 µm | ||||
| Coating Diameter | 160 to 2000 µm (In Fiber holder) 160 to 900 µm (Coating clamp splice) |
160 to 1300 µm (In Fiber holder) 160 to 900 µm (Coating clamp splice) |
|||
| Fiber Cleave Length | 3 to 5 mm (Coating clamp splice) 8 to 11 mm (Cladding clamp splice) |
||||
| Typical Splice Loss*² | SM(ITU-T G652): 0.014 dB | ||||
| Typical Extinction Ratio*² | – | -36.8dB*³ (Angle offset: 0.6 degree) | |||
| Return Loss | >60 dB | ||||
| Typical Splice Time*⁴ | 15s (SM by cladding clamp splice) | 15s (SM by cladding clamp splice) 40s (cladding clamp splice) |
|||
| Tension Strength | 1.96 (+0% to +20%) | ||||
| Applicable Protection Sleeve Length | 10 to 60 mm | ||||
| Typical Heat Time | 35s (S922:40 mm sleeve) | ||||
| Splice Programs | Max.200 | ||||
| Heater Programs | Max.100 | ||||
| Splice Data Storage | Max. 1000 including 4 images before and after splice | ||||
| Fiber Image Magnification on LCD | 104X, 278X or 556X | ||||
| Dimension | 210W X 180D X 140H mm | ||||
| Weight (without Battery) | 4.5 kg | 4.75 kg | |||
| Monitor | 4.3" wide color LCD with touch panel | ||||
| Data Output | USB ver. 2.0 type A: 1 port USB ver. 2.0 mini B: 1 port |
||||
| Battery Capacity (optional)*⁵ | Typical 60 splice / heat cycles | ||||
| Operating Temperature | 0 to 40 °C | ||||
| Storage Temperature | -40 to 60 °C | ||||
| Humidity | 0 to 90% (Non-condensing) | ||||
| Power Source | AC input 100 to 240V (50/60Hz) | ||||
| Note | *1 Fibers should be applied to ITU-T standard. In case of other fibers, depending on the type of fiber, the optimization of splice program may be needed or the splice result may not be satisfactory. *2 These are references. Depending on the environment and conditions, the numbers may vary. *3 Extinction ratio -36.8dB is measured under the conditions where that the initial extinction ratio is -40dB and the splice has 0.6 degree of rotation offset. *4 This value is a reference. Depending on the type of fiber and the condition of the fiber on the splicer, the numbers may vary. *5 This value can be produced using a fully-charged, brand new battery at room temperature of 20 degrees C. Depending on the condition of the battery and operating environment, the numbers may vary. |
||||
| Standard Package | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Item | P/N | Quantity S185LDF -00 | Quantity S185LDF -01 | Quantity S185LDF -10 | Quantity S185LDF -11 | Quantity S185PMLDF -00 | Quantity S185PMLDF -01 | Quantity S185PMLDF -10 | Quantity S185PMLDF -11 |
| S185LDF Main body | S185LDF-X-A-0001 | 1 | 1 | 1 | 1 | – | – | – | – |
| S185PMLDF Main body | S185PMLDF-X-A-0001 | – | – | – | – | 1 | 1 | 1 | 1 |
| Hard Carrying Case | HCC-12 | – | 1 | – | 1 | – | 1 | – | 1 |
| Built-in Battery Pack | S947B | – | – | 1 | 1 | – | – | 1 | 1 |
| AC Adapter | S981A | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
| AC Cable Cord | – | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
| Z Stage Lock | ZL-01 | 1 pair | 1 pair | 1 pair | 1 pair | 1 pair | 1 pair | 1 pair | 1 pair |
| Spare Electrode | ELR-03 | 1 pair | 1 pair | 1 pair | 1 pair | 1 pair | 1 pair | 1 pair | 1 pair |
| Electrode Sharpener | D5111 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
| Cleaning Brush | VGC-01 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
| User Manual | – | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
| Ordering Number Form S185 A – B C | |||
|---|---|---|---|
| Mark | Category | Code | Remark |
| A | Splicer model | LDF PMLDF |
S185LDF S185PMLDF |
| B | Battery | 0 1 |
None Included |
| C | Hard carrying case | 0 1 |
None Included |
| Optical Components | ||
|---|---|---|
| Item | P/N | Quantity |
| 160 μm Coating Fiber Holder | S713S-160 | 1 pair |
| 250 μm Coating Fiber Holder | S713S-250 | 1 pair |
| 400 μm Coating Fiber Holder | S713S-400 | 1 pair |
| 650 μm Coating Fiber Holder | S713S-650 | 1 pair |
| 900 μm Coating Fiber Holder | S713S-900 | 1 pair |
| 1300 μm Coating Fiber Holder | S713S-1300 | 1 pair |
| Customized Fiber Holder*⁶ | S713S-XXX | 1 pair |
| Hard Carrying Case | HCC-12 | 1 |
| Built-in Battery Pack | S947B | 1 |
| USB Cable | USB-01 | 1 |
| Wi-Fi Dongle | WFD-01 | 1 |
| *6 Availability of a suitable size Fiber holder depends on the coating diameter of the fiber being spliced. | ||
| Related Tools | ||
|---|---|---|
| Item | Part Number | Specification |
| Stripper | S218R-Plus 3SAE Thermal Stripper |
Cladding diameter 125 μm only Cladding diameter 30 to 1000 μm |
| Cleaver | S326A NorthLab ProCleave SD 3SAE LCCII |
Cladding diameter 125 μm only Cladding diameter 125 to 550 μm only Cladding diameter 125 to 1000 μm only |
| Cleaner | 3SAE Ultrasonic Cleaner | – |
| Protection Sleeve | S921/S922 S928A-20/25/35 |
Coating diameter 900 μm or less Coating diameter 400 μm or less |
The products and/or technical information presented in this publication may be subject to the application of the Foreign Exchange and Foreign Trade Act and other related laws and regulations in Japan. In addition, the Export Administration Regulations (EAR) of the United States may be applicable.
In cases where exporting or reexporting the products and/or technical information presented in this publication, customers are responsible for following the necessary procedures at their own risk and expense. Please contact the Ministry of Economy, Trade and Industry of Japan or the Department of Commerce of the United States for details about procedures.
For additional information please contact your sales representative. You can also visit our website at www.lightera.com or call 1-888-FIBERHELP (1-888-342-3743) USA or 1-770-798-5555 outside the USA. For a full list of our certifications, visit our website.
Lightera reserves the right to make changes to the product(s) described in this document at any time without notice. This document is for informational purposes only and is not intended to modify or supplement any Lightera warranties or specifications relating to any of its products or services.
Compare features, sizes, models to find the perfect option for you