| Description |
S185HS
|
S185PM
|
| Applicable Fibers*¹ |
SM, MM, DS, NZDS, High-Index, EDF |
SM, MM, DS, NZDS, High-Index, EDF, PMF |
| Cladding Diameter |
80 to 150 μm |
80 to 150 μm |
| Coating Diameter |
160 to 2000 μm (In Fiber holder) 160 to 900 μm (Coating clamp splice) |
160 to 1300 μm (In Fiber holder) 160 to 900 μm (Coating clamp splice) |
| Fiber Cleave Length |
3 to 4 mm (Coating clamp splice) 8 to 11 mm (Cladding clamp splice) |
3 to 4 mm (Coating clamp splice) 8 to 11 mm (Cladding clamp splice) |
| Typical Splice Loss*² |
SM (ITU-T G652): 0.014 dB |
SM (ITU-T G652): 0.014 dB |
| Typical Extinction Ratio*² |
– |
PANDA: 40 dB*³ (Angle offset: 0.6 degree) |
| Return Loss |
>60 dB |
>60 dB |
| Typical Splice Time*⁴ |
15 S (SM by cladding clamp splice) |
15 S (SM by cladding clamp splice) 40 s (PANDA by cladding clamp splice) |
| Tension Strength |
1.96 N (+0% to +20%) |
1.96 N (+0% to +20%) |
| Applicable Protection Sleeve Length |
10 to 60 mm |
10 to 60 mm |
| Typical Heat Time |
35 S (S922:40 mm sleeve) |
35 S (S922:40 mm sleeve) |
| Splice Programs |
Max.200 |
Max.200 |
| Heater Programs |
Max.100 |
Max.100 |
| Splice Data Storage |
Max. 1000 including 4 images before and after splice |
Max. 1000 including 4 images before and after splice |
| Fiber Image Magnification on LCD |
104 X, 278 X or 556 X |
104 X, 278 X or 556 X |
| Dimension |
210 W X 180 D X 150 H mm |
210 W X 180 D X 150 H mm |
| Weight (without Battery) |
4.5 kg |
4.75 kg |
| Monitor |
4.3" wide color LCD with touch panel |
4.3" wide color LCD with touch panel |
| Data Output |
USB ver. 2.0 type A: 1 port USB ver. 2.0 mini B: 1 port |
USB ver. 2.0 type A: 1 port USB ver. 2.0 mini B: 1 port |
| Battery Capacity (optional)*⁵ |
Typical 60 splice / heat cycles |
Typical 60 splice / heat cycles |
| Operating Temperature |
0 to 40°C |
0 to 40°C |
| Storage Temperature |
-40 to 60°C |
-40 to 60°C |
| Humidity |
0 to 90% (Non-condensing) |
0 to 90% (Non-condensing) |
| Power Source |
AC input 100 to 240 V (50/60 Hz) |
AC input 100 to 240 V (50/60 Hz) |
| Note |
*1 Fibers should be applied to ITU-T standard. In case of other fibers, depending on the type of fiber, the optimization of splice program may be needed or the splice result may not be satisfied. *2 These are references. Depending on the environment and condition, the number vary. *3 Extinction ratio 40 dB is measured in the condition that the initial extinction ratio is more than 50 dB and there is the splice with 0.6 degree of rotation offset. *4 This value is references. Depending on the type of fiber and condition of fiber on splicer, the number can vary. *5 This value can produce using fully charged brand new battery at room temperature 20 degree C. Depending on the condition of the battery and operation environment, the number can vary. |