Home chevron_right Products – Optical Fiber & Connectivity Solutions  chevron_right Fiber Optic Cables chevron_right OPTICAL CABLE CFOI-BLI-UB 48F G-657A2 LSZH GY – EUROCLASS Dca (s2, d2, a1) – (SIMPLUSLAN FTTA)
Descontinuado
Part no - 19850030

OPTICAL CABLE CFOI-BLI-UB 48F G-657A2 LSZH GY – EUROCLASS Dca (s2, d2, a1) – (SIMPLUSLAN FTTA)

All Dielectric Optical Cable recommended for indoor building areas, especially on vertical backbones in FTTA (Fiber To The Apartment) systems for voice, data and imaging traffic Internal installations in conduit and conduit infrastructure. Consisting of optical units of the micromodule type, with primary acrylate coating. Dielectric wires are placed on the micromodule assembly. On the assembly an outer layer is applied using a non-flame-propagating thermoplastic material.

All Dielectric Optical Cable recommended for indoor building areas, especially on vertical backbones in FTTA (Fiber To The Apartment) systems for voice, data and imaging traffic Internal installations in conduit and conduit infrastructure. Consisting of optical units of the micromodule type, with primary acrylate coating. Dielectric wires are placed on the micromodule assembly. On the assembly an outer layer is applied using a non-flame-propagating thermoplastic material.

Construction 

Dielectric;

Micro modules;

Single mode.

Description 

Totally dielectric optical cable, consisted of optical units denominated micromodules. Optical fibers, coated with acrylate, are placed inside micromudules. Dielectric yarns are placed over micromodules to guarantee traction resistance. Over this set a flame retardant cover is applied.

Application 

Appliable as vertical cable in fiber optic projects

Installation Environment 

Indoor.

Operation Environment 

Vertical installations in ducts.

Standard 

  • ABNT NBR 14771;
  • GR-409: Indoor Fiber Optic Cable;
  • ITU-T G.657: "Characteristics of a bending-loss insensitive single-mode optical fibre and cable";
  • EN 60332-1-2: “Tests on electric and optical fibre cables under fire conditions – Part 1-2: Test for vertical flame propagation for a single insulated wire or cable – Procedure for 1 kW pre-mixed flame”;
  • EN 61034-2: “Measurement of smoke density of cables burning under defined conditions – Part 2: Test procedure and requirements”;
  • EN 50399: "Common test method for cables under fire conditions. Heat release and smoke production measurement on cables during flame spread test. Test apparatus, procedures, results";
  • EN 50267-2-3: "Common test method for cables under fire conditions. Test on gases evolved during combustion of materials from cables. Procedures. Determination of degree of acidity of gases for cables by determination of the weighted average of pH and conductivity";
  • Standard EN50399:
    • Total heat released: ≤ 70 MJ;
    • Peak heat release rate: ≤ 400 kW;
    • Fire index growth rate: ≤ 1300 W/s;
  • Standard EN 60332-1-2:
    • Height: ≤ 425 mm;

Certifications 

Dca (s2, d2, a1).

Optical Fiber 

BLI (Bending Loss Insensitive) G-657A.

Fiber Coating 

Acrylate.

Fiber Identification 

FIBER:

  1. Blue;
  2. Orange;
  3. Green;
  4. Brown;
  5. Grey;
  6. White;
  7. Red;
  8. Black.

MICROMODULE:

  1. Blue;
  2. Orange;
  3. Green;
  4. Brown;
  5. Grey;
  6. White;
  7. Red;
  8. Black.

Compare products and choose the best one

Compare features, sizes, models to find the perfect option for you

Compare products

Americas Asia & Oceania Africa Europe Middle East